Model

N/A PRO REMOTE 25' 115

Power Requirements

N/A 115 VAC

Ambient Temperature Range

N/A -40°F to 185°

Output Relay

N/A DPDT 10 Amp at 250 VAC

Probe Type

N/A 6.5" Shielded, DELRIN Sleeved Probe

Pressure

N/A 500 PSI, 3/4" Mount

Sensitivity Setting

N/A Adjustable Sensitivity to <1 Picofarad

Calibration Type

N/A "Quick Set" Coarse / Fine Single Turn Potentiometers

Fail-Safe

N/A Switch Selectable High / Low

Time Delay

N/A Dual Delay Covered / Uncovered up to 30-Seconds

Enclosure

N/A Cast Aluminum, Bolt-On Cover FDA Recognized Finish

Mounting

N/A 3/4" NPT SS Fitting f/Bare & DELRIN Sleeved Probes

PRO-Shield

N/A Compensates for Material Build-Up on Sensing Probe

Approvals

N/A CSA Listed NEMA 4X, 5, & 12 Intrinsically Safe

Status Indicator Relay

N/A Internal LED Indicates Material in Contact with Probe

Enclosure Electronics

N/A Plastic

Electronics Type

N/A CSA Listed Class II, Group E, F, & G NEMA 4X, 5, & 12