• Economical, Reliable, and Durable Point-Level Detection
  • Low Profile Mounting
  • Multiple Diaphragm Materials
  • Over-Pressure Protection
  • Ultra-Sensitive Switch Option
  • UL, CSA Approvals
  • Industry's Preferred Diaphragm Unit for Over 30 Years
  • Economical Point-Level Detection in Bins and Hoppers
  • Ultra-Sensitive Switch for Lightweight Materials
  • Unique External Installation and Maintenance
Monitor's line of BINATROL® diaphragm bin monitors consists of economical, reliable, and durable point-level controls for point-level detection of dry bulk materials. The units can be used to eliminate bin overflow, maintain a predetermined material level, indicate plugging of chutes or conveyors, or provide level control functions. The flush mount, non-intrusive BINATROL® units are ideally used when vessel size or internal clearance is limited, or where protrusion into a vessel is not acceptable. All installation and servicing, including diaphragm replacement and sensitivity adjustment, can be done from outside the vessel.
Unit of Measure
Items
Binatrol® Diaphragm Bin Monitor

Binatrol® Diaphragm Bin Monitor

Binatrol® Diaphragm Bin Monitor

Binatrol® Diaphragm Bin Monitor

Binatrol® Diaphragm Bin Monitor

Binatrol® Diaphragm Bin Monitor

Binatrol® Diaphragm Bin Monitor

Binatrol® Diaphragm Bin Monitor

Binatrol® Diaphragm Bin Monitor

Binatrol® Diaphragm Bin Monitor
Description N/A
  • Economical, Reliable, and Durable Point-Level Detection
  • Low Profile Mounting
  • Multiple Diaphragm Materials
  • Over-Pressure Protection
  • Ultra-Sensitive Switch Option
  • UL, CSA Approvals
  • Industry's Preferred Diaphragm Unit for Over 30 Years
  • Economical Point-Level Detection in Bins and Hoppers
  • Ultra-Sensitive Switch for Lightweight Materials
  • Unique External Installation and Maintenance
Monitor's line of BINATROL® diaphragm bin monitors consists of economical, reliable, and durable point-level controls for point-level detection of dry bulk materials. The units can be used to eliminate bin overflow, maintain a predetermined material level, indicate plugging of chutes or conveyors, or provide level control functions. The flush mount, non-intrusive BINATROL® units are ideally used when vessel size or internal clearance is limited, or where protrusion into a vessel is not acceptable. All installation and servicing, including diaphragm replacement and sensitivity adjustment, can be done from outside the vessel.
Model Type N/A G N/A G N/A G N/A G N/A GX
Diaphragm Material N/A Neoprene N/A Neoprene N/A Teflon® N/A Teflon® N/A Neoprene
Switch Type N/A Standard Switch N/A Ultra-Sensitive Switch N/A Standard Switch N/A Ultra-Sensitive Switch N/A Standard Switch
Power Requirements N/A None
Max. Output N/A SPDT dry contact, 15A at 250 VAC
Sensitivity (Min. Material Density) N/A 15 lb/ft³240 kg/m³ N/A 10 lb/ft³160 kg/m³ N/A 15 lb/ft³240 kg/m³ N/A 10 lb/ft³160 kg/m³ N/A 15 lb/ft³240 kg/m³
Enclosure N/A Die Cast Aluminum, Powder Coated
Enclosure Protection N/A IP56 N/A IP56 N/A IP56 N/A IP56 N/A NEMA 4
Mounting Connection N/A 7.5 in190.5 mm
Wire Entry N/A 1/2 NPT
Operating Temperature N/A -40° to 180 ºF-40° to 82 ºC N/A -40° to 180 ºF-40° to 82 ºC N/A -40° to 250 ºF-40° to 121 ºC N/A -40° to 250 ºF-40° to 121 ºC N/A -40° to 180 ºF-40° to 82 ºC
Weight N/A 3.25 lb1.5 kg
Approvals N/A CSA Ordinary Locations N/A CSA Ordinary Locations N/A CSA Ordinary Locations N/A CSA Ordinary Locations N/A UL/CSA Class II, Div. 1, 2, Groups F, G; CE marking (ordinary locations only)
Min. Vessel Diameter1 N/A 12 ft
  • 1 Smaller vessels will require modifications and extra gasketing.
Copyright © 2017 Airmatic Inc.,  All Rights Reserved