Serving Industry Since 1944
All Categories > Dust Management > MONITOR® Broken Bag Detectors
for Dust Collectors
> SiloPatrol® SE Inventory Management System - Human Machine Interface > View Items
 
Download PDF Download PDF     Printable Page     Email Email This Page     Save To Favorites Save To Favorites

SiloPatrol® SE Inventory Management System - Human Machine Interface

Check up to five results to perform an action.


  • Extreme Conditions - No Problem!
  • Leader in Cable-Based, Smart-Sensor Systems and Value
  • Unprecedented and Unsurpassed Sensor Durability & Application Reliability
  • Hall-Effect Technology Enhances Application Reliability
  • Unique, Network-Capable, PC-Based Inventory Management Software
  • Affordable, Wireless-Sensor Interface Available, Unmatched RMI/VMI Solutions
  • Uses Innovative, Hall-Effect Technology To Maximize Application Reliability By Effectively Regulating Power To Motor Under Varying Load Conditions
  • Industry-Best Measurement Resolution Of 1/100'(0.12"; 3.05 mm)
  • Virtually Maintenance Free
  • Split-Compartment Enclosure Isolates Electronics And Measurement Optics From Process Material
  • Fast, Easy Servicing Of Process Seal
  • PC-Based Inventory Solutions Or Simple HMI Keypad/Display
  • RS-485 Pulse Or Analog Sensor Output Available
  • Hazardous Location Sensor Version
  • Wireless-Sensor Interface Solutions
  • Auxiliary System Outputs Available






Compare Items
   
  Results 1 - 6 of 6 1 

Item #

Operating Voltage

Channels

Ambient Operating Temperature

Model Selection

6-8611-21 115 VAC, 50/60 Hz 2 -4 to 131 ºF
-20 to 55 ºC
APPROVALS
The HMI is designed for Ordinary Locations. The HMI also carries the CE Mark.

NUMBER OF CHANNELS
The HMI is available in 2-, 8- or 16-channel configura tions. The individually addressable SMU "smart" output sensors are wired to the HMI using a single RS- 485 network cable. Multiple SMU "smart" output sensors (up to a maximum of 16) can be connected to the HMI using a single RS-485 network cable.
6-8621-21 230 VAC, 50/60 Hz 2 -4 to 131 ºF
-20 to 55 ºC
APPROVALS
The HMI is designed for Ordinary Locations. The HMI also carries the CE Mark.

NUMBER OF CHANNELS
The HMI is available in 2-, 8- or 16-channel configura tions. The individually addressable SMU "smart" output sensors are wired to the HMI using a single RS- 485 network cable. Multiple SMU "smart" output sensors (up to a maximum of 16) can be connected to the HMI using a single RS-485 network cable.
6-8611-81 115 VAC, 50/60 Hz 8 -4 to 131 ºF
-20 to 55 ºC
APPROVALS
The HMI is designed for Ordinary Locations. The HMI also carries the CE Mark.

NUMBER OF CHANNELS
The HMI is available in 2-, 8- or 16-channel configura tions. The individually addressable SMU "smart" output sensors are wired to the HMI using a single RS- 485 network cable. Multiple SMU "smart" output sensors (up to a maximum of 16) can be connected to the HMI using a single RS-485 network cable.
6-8621-81 230 VAC, 50/60 Hz 8 -4 to 131 ºF
-20 to 55 ºC
APPROVALS
The HMI is designed for Ordinary Locations. The HMI also carries the CE Mark.

NUMBER OF CHANNELS
The HMI is available in 2-, 8- or 16-channel configura tions. The individually addressable SMU "smart" output sensors are wired to the HMI using a single RS- 485 network cable. Multiple SMU "smart" output sensors (up to a maximum of 16) can be connected to the HMI using a single RS-485 network cable.
6-8611-61 115 VAC, 50/60 Hz 16 -4 to 131 ºF
-20 to 55 ºC
APPROVALS
The HMI is designed for Ordinary Locations. The HMI also carries the CE Mark.

NUMBER OF CHANNELS
The HMI is available in 2-, 8- or 16-channel configura tions. The individually addressable SMU "smart" output sensors are wired to the HMI using a single RS- 485 network cable. Multiple SMU "smart" output sensors (up to a maximum of 16) can be connected to the HMI using a single RS-485 network cable.
6-8621-61 230 VAC, 50/60 Hz 16 -4 to 131 ºF
-20 to 55 ºC
APPROVALS
The HMI is designed for Ordinary Locations. The HMI also carries the CE Mark.

NUMBER OF CHANNELS
The HMI is available in 2-, 8- or 16-channel configura tions. The individually addressable SMU "smart" output sensors are wired to the HMI using a single RS- 485 network cable. Multiple SMU "smart" output sensors (up to a maximum of 16) can be connected to the HMI using a single RS-485 network cable.
  Results 1 - 6 of 6 1 